Siphon or gravity fed for non-pressurised applications
Standard Models:
1/8” – SF8010SS, SF8020SS and SF8030SS
1/4″ – SF1010SS, SF1020SS and SF1030SS
No Drip Models:
1/8” – SF9010SS, SF9020SS and SF9030SS
1/4″ –SF2010SS, SF2020SS and SF2030SS
1/8” Siphon Fed Flat Fan Pattern Atomizing Nozzles are great where no liquid pressure is available and a thin coating is needed over a wide band. Flow rate is adjustable via the adjusting valve. Siphon fed nozzles work best with a suction height of 914mm (36″) or less. Since these nozzles are siphon fed, the compressed airflow draws the liquid in and mixes it internally. Liquid flow is dependent both on the gravity or suction height and the airflow. Siphon Fed Flat Fan Pattern Atomizing Nozzles are the best choice where liquid is needed over a broad band such as a moving assembly line.
EXAIR’s patented† 1/8” No Drip Siphon Fed Flat Fan Pattern Atomizing Nozzles work in the same way as the EXAIR standard atomizing nozzles do but have the added benefit of positively stopping liquid flow when compressed air is shut off.
All models use stainless steel construction for durability and corrosion resistance.
†Patent #9156045
Standard Models | No Drip Models | 1/8″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||||||||
Air Pressure | Width | Maximum Depth | |||||||||
A | B | C | |||||||||
PSI | BAR | in | cm | in | cm | in | cm | ft | m | ||
SF8010SS | SF9010SS | 10 | 0.7 | 7 | 18 | 9 | 23 | 12 | 30 | 2 | 0.6 |
20 | 1.4 | 7 | 18 | 9 | 23 | 12 | 30 | 2 | 0.6 | ||
30 | 2.1 | 7 | 18 | 9 | 23 | 12 | 30 | 2 | 0.6 | ||
SF8020SS | SF9020SS | 20 | 1.4 | 8 | 20 | 9 | 23 | 12 | 30 | 2 | 0.6 |
30 | 2.1 | 9 | 23 | 11 | 28 | 13 | 33 | 2 | 0.6 | ||
40 | 2.8 | 9 | 23 | 10 | 25 | 13 | 33 | 2 | 0.6 | ||
50 | 3.4 | 7 | 18 | 8 | 20 | 9 | 23 | 3 | 0.9 | ||
SF8030SS | SF9030SS | 20 | 1.4 | 7 | 18 | 8 | 20 | 9.5 | 24 | 2 | 0.6 |
30 | 2.1 | 7 | 18 | 8 | 20 | 9.5 | 24 | 2 | 0.6 | ||
40 | 2.8 | 7 | 18 | 8 | 20 | 9.5 | 24 | 3 | 0.9 | ||
50 | 3.4 | 7 | 18 | 8 | 20 | 9.5 | 24 | 3 | 0.9 |
Droplet size can be adjusted by varying either the air or liquid pressure. An increase in air pressure or decrease in liquid pressure will generally produce a smaller droplet size. The Spray Angle is the trigonometric angle created by the width of the spray pattern and the distance at which it is measured.
Learn MoreStandard Models | No Drips Models |
1/8″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||||||||||||||||||
Air | Gravity Head | Siphon Height | |||||||||||||||||||
Pressure | |||||||||||||||||||||
PSI | BAR | SCFM | SLPM | 18″ | 46cm | 12″ | 30cm | 6″ | 15cm | 4″ | 10cm | 8″ | 20cm | 12″ | 30cm | 24″ | 61cm | 36″ | 91cm | ||
SF8010SS | SF9010SS | 10 | 0.7 | 1.07 | 30.3 | 0.32 | 1.2 | 0.30 | 1.1 | 0.25 | 1.0 | 0.24 | 0.9 | 0.23 | 0.9 | 0.18 | 0.7 | 0.17 | 0.7 | 0.14 | 0.5 |
20 | 1.4 | 1.31 | 37.1 | 0.36 | 1.4 | 0.35 | 1.3 | 0.31 | 1.2 | 0.31 | 1.2 | 0.30 | 1.1 | 0.25 | 0.9 | 0.23 | 0.9 | 0.19 | 0.7 | ||
60 | 4.1 | 1.69 | 47.9 | 0.43 | 1.6 | 0.40 | 1.5 | 0.35 | 1.3 | 0.34 | 1.3 | 0.32 | 1.2 | 0.27 | 1.0 | 0.26 | 1.0 | 0.24 | 0.9 | ||
SF8020SS | SF9020SS | 20 | 1.4 | 1.81 | 51.3 | 1.52 | 5.8 | 1.33 | 5.0 | 1.10 | 4.2 | 0.80 | 0.9 | 0.76 | 2.9 | 0.71 | 2.7 | 0.50 | 1.9 | 0.36 | 1.4 |
30 | 2.1 | 2.30 | 65.1 | 1.18 | 4.5 | 1.16 | 4.4 | 1.06 | 4.0 | 0.85 | 3.2 | 0.79 | 3.0 | 0.77 | 2.9 | 0.52 | 2.0 | 0.44 | 1.7 | ||
40 | 2.8 | 2.83 | 80.2 | 1.01 | 3.8 | 0.90 | 3.4 | 0.83 | 3.1 | 0.70 | 2.6 | 0.67 | 2.5 | 0.63 | 2.4 | 0.42 | 1.6 | 0.27 | 1.0 | ||
50 | 3.4 | 3.34 | 94.6 | 0.85 | 3.2 | 0.71 | 2.7 | 0.59 | 2.2 | 0.48 | 1.8 | 0.41 | 1.6 | 0.51 | 1.9 | 0.32 | 1.2 | — | — | ||
SF8030SS | SF9030SS | 20 | 1.4 | 1.78 | 50.3 | 1.45 | 5.5 | 1.40 | 5.3 | 1.38 | 5.2 | 0.94 | 3.6 | 0.90 | 3.4 | 0.77 | 2.9 | 0.72 | 2.7 | 0.61 | 2.3 |
30 | 2.1 | 2.24 | 63.5 | 1.16 | 4.4 | 1.12 | 4.2 | 1.10 | 4.2 | 1.00 | 3.8 | 0.98 | 3.7 | 0.86 | 3.2 | 0.81 | 3.1 | 0.69 | 2.6 | ||
40 | 2.8 | 2.75 | 77.8 | 0.98 | 3.7 | 0.96 | 3.6 | 0.85 | 3.2 | 0.90 | 3.4 | 0.87 | 3.3 | 0.79 | 3.0 | 0.66 | 2.5 | 0.52 | 2.0 | ||
50 | 3.4 | 3.00 | 85.0 | 0.83 | 3.2 | 0.79 | 3.0 | 0.70 | 2.6 | 0.75 | 2.8 | 0.69 | 2.6 | 0.66 | 2.5 | 0.51 | 1.9 | 0.44 | 1.7 |
1/8″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||
Maximum Liquid Flow Rate | Standard Model |
No Drip Model |
|
GPH | LPH | ||
0.4 | 1.5 | BPSF8010SS | BPSF9010SS |
1.5 | 5.7 | BPSF8020SS | BPSF9020SS |
1.45 | 5.5 | BPSF8030SS | BPSF9030SS |
Mounting Brackets For Atomizing Spray Nozzles | |||
Model | Description | ||
901786 | Mounting Bracket for 1/8″ Atomizing Spray Nozzles | ||
901318 | Mounting Bracket for 1/4″ Atomizing Spray Nozzles | ||
901556 | Mounting Bracket for 1/2″ Atomizing Spray Nozzles |
EXAIR's EFC™ is a user-friendly electronic flow control for compressed air that is designed to minimise compressed air use on blowoff, drying, cooling, conveying and static elimination operations. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present. The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.
Learn MoreWith proper filtration of dirt, moisture and oil from the compressed air supply, EXAIR compressed air products will operate for years with no maintenance required. Use a 5 micron or smaller filter separator on the compressed air supply. To prevent problems associated with oil, use a 0.03 micron or smaller oil removal filter on the compressed air supply. Pressure regulators permit easy selection of the operating pressure, providing infinite control of flow, force and air consumption
Learn MorePlease login to access the PDF Catalogue.
1/4″ Siphon Fed Flat Fan Pattern Atomizing Nozzles are great where no liquid pressure is available and a thin coating is needed over a wide band. Flow rate is adjustable via the adjusting valve. Siphon nozzles work best with a suction height of 914mm (36″) or less. Since these nozzles are siphon fed, the compressed airflow draws the liquid in and mixes it internally. Liquid flow is dependent both on the gravity or suction height and the airflow. Siphon Fed Flat Fan Pattern Atomizing Nozzles are the best choice where liquid is needed over a broad band such as a moving assembly line.
EXAIR’s patented† 1/4” No Drip Siphon Fed Flat Fan Pattern Atomizing Nozzles work in the same way as the EXAIR standard atomizing nozzles do but have the added benefit of positively stopping liquid flow when compressed air is shut off.
All models use stainless steel construction for durability and corrosion resistance.
†Patent #9156045
A Model SF1020SS is used to apply a light coating of oil to prevent socketsfrom rusting prior to a packaging operation.
Standard Models | No Drip Models | 1/4″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||||||||
Air Pressure | Width | Maximum Depth | |||||||||
A | B | C | |||||||||
PSI | BAR | in | cm | in | cm | in | cm | ft | m | ||
SF1010SS | SF2010SS | 10 | 0.7 | 9 | 23 | 11 | 28 | 13 | 33 | 5 | 1.5 |
20 | 1.4 | 10 | 25 | 12 | 30 | 14 | 36 | 6 | 1.8 | ||
30 | 2.1 | 11 | 28 | 13 | 33 | 15 | 38 | 7 | 2.1 | ||
SF1020SS | SF2020SS | 20 | 1.4 | 10 | 25 | 14 | 36 | 19 | 48 | 6 | 1.8 |
30 | 2.1 | 11 | 28 | 15 | 38 | 21 | 53 | 7 | 2.1 | ||
40 | 2.8 | 13 | 33 | 16 | 41 | 23 | 58 | 6 | 1.8 | ||
50 | 3.4 | 14 | 36 | 18 | 46 | 25 | 64 | 6 | 1.8 | ||
SF1030SS | SF2030SS | 20 | 1.4 | 9 | 23 | 11 | 28 | 15 | 38 | 8 | 2.4 |
30 | 2.1 | 10 | 25 | 13 | 33 | 17 | 43 | 9 | 2.7 | ||
40 | 2.8 | 11 | 28 | 14 | 36 | 17 | 43 | 10 | 3.0 | ||
50 | 3.4 | 11 | 28 | 14 | 36 | 18 | 46 | 11 | 3.4 |
Droplet size can be adjusted by varying either the air or liquid pressure. An increase in air pressure or decrease in liquid pressure will generally produce a smaller droplet size. The Spray Angle is the trigonometric angle created by the width of the spray pattern and the distance at which it is measured.
Learn MoreStandard Models | No Drip Models | 1/4″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||||||||||||||||||
Air | Gravity Head | Siphon Height | |||||||||||||||||||
Pressure | |||||||||||||||||||||
PSI | BAR | SCFM | SPLM | 18″ | 46cm | 12″ | 30cm | 6″ | 15cm | 4″ | 10cm | 8″ | 20cm | 12″ | 30cm | 24″ | 61cm | 36″ | 91cm | ||
SF1010SS | SF2010SS | 10 | 0.7 | 0.9 | 25.5 | 0.4 | 1.5 | 0.3 | 1.1 | 0.3 | 1.1 | 0.2 | 0.8 | 0.2 | 0.8 | 0.2 | 0.8 | 0.2 | 0.8 | 0.1 | 0.4 |
20 | 1.4 | 1.3 | 36.8 | 0.4 | 1.5 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.2 | 0.8 | 0.2 | 0.8 | ||
30 | 2.1 | 1.7 | 48.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | 0.3 | 1.1 | — | — | — | — | — | — | ||
SF1020SS | SF2020SS | 20 | 1.4 | 2.3 | 65.1 | 1.2 | 4.5 | 1.1 | 4.2 | 1.0 | 3.8 | 0.9 | 3.4 | 0.8 | 3.0 | 0.8 | 3.0 | 0.6 | 2.3 | 0.5 | 1.9 |
30 | 2.1 | 2.9 | 82.1 | 1.1 | 4.2 | 1.1 | 4.2 | 1.0 | 3.8 | 0.8 | 3.0 | 0.8 | 3.0 | 0.8 | 3.0 | 0.6 | 2.3 | 0.5 | 1.9 | ||
40 | 2.8 | 3.5 | 99.1 | 1.0 | 3.8 | 0.9 | 3.4 | 0.8 | 3.0 | 0.7 | 2.6 | 0.7 | 2.6 | 0.7 | 2.6 | 0.5 | 1.9 | 0.4 | 1.5 | ||
50 | 3.4 | 4.3 | 122 | 0.8 | 3.0 | 0.7 | 2.6 | 0.5 | 1.9 | 0.5 | 1.9 | 0.4 | 1.5 | 0.3 | 1.1 | — | — | — | — | ||
SF1030SS | SF2030SS | 20 | 1.4 | 2.2 | 62.3 | 1.8 | 6.8 | 1.6 | 6.1 | 1.5 | 5.7 | 1.4 | 5.3 | 1.4 | 5.3 | 1.3 | 4.9 | 1.1 | 4.2 | 1.0 | 3.8 |
30 | 2.1 | 2.8 | 79.2 | 1.9 | 7.2 | 1.8 | 6.8 | 1.8 | 6.8 | 1.7 | 6.4 | 1.7 | 6.4 | 1.6 | 6.1 | 1.4 | 5.3 | 1.2 | 4.5 | ||
40 | 2.8 | 3.3 | 93.4 | 1.8 | 6.8 | 1.8 | 6.8 | 1.7 | 6.4 | 1.6 | 6.1 | 1.6 | 6.1 | 1.5 | 5.7 | 1.3 | 4.9 | 1.2 | 4.5 | ||
50 | 3.4 | 4.0 | 113 | 1.6 | 6.1 | 1.5 | 5.7 | 1.4 | 5.3 | 1.4 | 5.3 | 1.3 | 4.9 | 1.3 | 4.9 | 1.1 | 4.2 | 1.0 | 3.8 |
1/4″ Siphon Fed Flat Fan Pattern Atomizing Nozzles | |||
Maximum Liquid Flow Rate | Standard Model |
No Drip Model |
|
GPH | LPH | ||
0.4 | 1.5 | BPSF1010SS | BPSF2010SS |
1.2 | 4.5 | BPSF1020SS | BPSF2020SS |
1.9 | 7.2 | BPSF1030SS | BPSF2030SS |
Mounting Brackets For Atomizing Spray Nozzles | |||
Model | Description | ||
901786 | Mounting Bracket for 1/8″ Atomizing Spray Nozzles | ||
901318 | Mounting Bracket for 1/4″ Atomizing Spray Nozzles | ||
901556 | Mounting Bracket for 1/2″ Atomizing Spray Nozzles |
EXAIR's EFC™ is a user-friendly electronic flow control for compressed air that is designed to minimise compressed air use on blowoff, drying, cooling, conveying and static elimination operations. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present. The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.
Learn MoreWith proper filtration of dirt, moisture and oil from the compressed air supply, EXAIR compressed air products will operate for years with no maintenance required. Use a 5 micron or smaller filter separator on the compressed air supply. To prevent problems associated with oil, use a 0.03 micron or smaller oil removal filter on the compressed air supply. Pressure regulators permit easy selection of the operating pressure, providing infinite control of flow, force and air consumption.
Learn MorePlease login to access the PDF Catalogue.
Copyright 2019 © Compressed Air Australia | Website Design Web365 Darwin