product-img

External Mix Narrow Angle Flat Fan Pattern

For pressure fed applications with independent air and liquid control

Standard Models:
1/8” – EF8010SS, EF8020SS, EF8030SS, E81040SSand E81050SS
1/4″ – EF1010SS, EF1020SS, EF1030SS and EF1040SS
1/2″ – EF5010SS

No Drip Models:
1/8” – EF9010SS, EF9020SS, EF9030SS, E91040SS and E91050SS
1/4″ –EF2010SS, EF2020SS, EF2030SS, and EF2040SS
1/2″ – EF6010SS

1/8” External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles

1/8” External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are great where liquid is needed over a more concentrated area than the Internal Mix Flat Fan nozzles. Since they are external mix, airflow and liquid flow can be controlled independently. External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are the best choice where thicker liquids for a heavy coating are needed over a narrow band, such as a paint line.

EXAIR’s patented† 1/8” No Drip External Mix Flat Fan Pattern Atomizing Nozzles work in the same way as the EXAIR standard atomizing nozzles do but have the added benefit of positively stopping liquid flow when compressed air is shut off.

All models use stainless steel construction for durability and corrosion resistance.

†Patent #9156045

Airflow Pattern

Spray Dimensions

Standard Models No Drip Models 1/8″ External Mix Flat Fan Pattern Atomizing Nozzles
Pressure Width Maximum Depth
Air Liquid A B C
PSI BAR PSI BAR in cm in cm in cm ft m
EF8010SS EF8010SS 10 0.7 10 0.7 4 10 5 13 4 10 4 1.2
30 2.1 20 1.4 4 10 5 13 6 15 6 1.8
30 2.1 30 2.1 4 10 5 13 6 15 6 1.8
50 3.4 40 2.8 4 10 5 13 8 20 8 2.4
EF8020SS EF8020SS 10 0.7 10 0.7 3 8 4.5 11 4 10 4 1.2
30 2.1 20 1.4 3 8 4.5 11 6 15 6 1.8
30 2.1 30 2.1 3 8 4.5 11 7 18 7 2.1
50 3.4 40 2.8 3 8 4.5 11 8 20 8 2.4
EF8030SS EF8030SS 10 0.7 10 0.7 4 10 5 13 5 13 5 1.5
30 2.1 20 1.4 4 10 5 13 7 18 7 2.1
30 2.1 30 2.1 4 10 5 13 8 20 8 2.4
50 3.4 40 2.8 4 10 5 13 9 23 9 2.7
EF8040SS EF8040SS 20 1.4 10 0.7 5.5 14 7 18 7 18 7 2.1
30 2.1 20 1.4 5.5 14 7 18 9 23 9 2.7
40 2.8 30 2.1 5.5 14 7 18 10 25 10 3.0
50 3.4 40 2.8 5.5 14 7 18 11 28 11 3.4
EF8050SS EF8050SS 30 2.1 10 0.7 7 18 9 23 9 23 9 2.7
40 2.8 20 1.4 7 18 9 23 10 25 10 3.0
70 4.8 40 2.8 7 18 9 23 12 30 12 3.7

Droplet Size and Spray Angle

Droplet size can be adjusted by varying either the air or liquid pressure. An increase in air pressure or decrease in liquid pressure will generally produce a smaller droplet size. The Spray Angle is the trigonometric angle created by the width of the spray pattern and the distance at which it is measured.

Learn More

Liquid Flow Rate

Standard Models No Drip Models 1/8″ External Mix Flat Fan Pattern Atomizing Nozzles
10 PSI/0.7 BAR Liquid 20 PSI/1.4 BAR Liquid 30 PSI/2.1 BAR Liquid 40 PSI/2.8 BAR Liquid
Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM
PSI BAR PSI BAR PSI BAR PSI BAR
EF8010SS EF9010SS 10 0.7 1.22 4.6 1.20 34.0 10 0.7 1.64 6.2 1.20 34.0 10 0.7 1.82 6.9 1.20 34.0 10 0.7 2.00 7.6 1.20 34.0
30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8
50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5
EF8020SS EF9020SS 10 0.7 2.00 7.6 1.20 34.0 10 0.7 2.56 9.7 1.20 34.0 10 0.7 2.67 10.1 1.20 34.0 10 0.7 2.93 11.1 1.20 34.0
30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8
50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5
EF8030SS EF9030SS 10 0.7 4.47 16.9 1.20 34.0 10 0.7 5.60 21.2 1.20 34.0 10 0.7 6.30 23.8 1.20 34.0 10 0.7 7.67 29.0 1.20 34.0
30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8 30 2.1 2.29 64.8
50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5 50 3.4 3.41 96.5
EF8040SS EF9040SS 20 1.4 8.67 32.8 1.95 55.2 20 1.4 10.75 40.7 1.95 55.2 20 1.4 13.00 49.2 1.95 55.2 20 1.4 14.42 54.6 1.95 55.2
30 2.1 2.50 70.8 30 2.1 2.5 70.8 30 2.1 2.5 70.8 30 2.1 2.5 70.8
40 2.8 3.13 88.6 40 2.8 3.13 88.6 40 2.8 3.13 88.6 40 2.8 3.13 88.6
50 3.4 3.68 104.2 50 3.4 3.68 104.2 50 3.4 3.68 104.2 50 3.4 3.68 104
EF8050SS EF9050SS 30 2.1 12.6 47.7 2.28 64.5 30 2.1 16.6 62.8 2.28 64.5 30 2.1 20.17 76.4 2.28 64.5 30 2.1 25.00 94.6 2.28 64.5
40 2.8 2.84 80.4 40 2.8 2.84 80.4 40 2.8 2.84 80.4 40 2.8 2.84 80.4
60 4.1 3.87 109.6 60 4.1 3.87 109.6 60 4.1 3.87 109.6 60 4.1 3.87 110
70 4.8 4.45 126.0 70 4.8 4.45 126.0 70 4.8 4.45 126.0 70 4.8 4.45 126

Dimensions

Standard Models
No Drip Models

Models

1/8″ External Mix Flat Fan Pattern Atomizing Nozzles
Maximum Liquid Flow Rate Standard
Model
No Drip
Model
GPH LPH
2.0 7.6 BPEF8010SS BPEF9010SS
2.9 11.0 BPEF8020SS BPEF9020SS
7.7 29.3 BPEF8030SS BPEF9030SS
14.4 54.7 BPEF8040SS BPEF9040SS
25.0 95.0 BPEF8050SS BPEF9050SS

 

Mounting Brackets For Atomizing Spray Nozzles
Model Description
901786 Mounting Bracket for 1/8″ Atomizing Spray Nozzles
901318 Mounting Bracket for 1/4″ Atomizing Spray Nozzles
901556 Mounting Bracket for 1/2″ Atomizing Spray Nozzles

Accessories

EFC Electronic Flow Control
Turn off the compressed air when it isn’t needed

EXAIR's EFC™ is a user-friendly electronic flow control for compressed air that is designed to minimise compressed air use on blowoff, drying, cooling, conveying and static elimination operations. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present. The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.

Learn More
Filters, Regulators, Valves & More

With proper filtration of dirt, moisture and oil from the compressed air supply, EXAIR compressed air products will operate for years with no maintenance required. Use a 5 micron or smaller filter separator on the compressed air supply. To prevent problems associated with oil, use a 0.03 micron or smaller oil removal filter on the compressed air supply. Pressure regulators permit easy selection of the operating pressure, providing infinite control of flow, force and air consumption.

Learn More

Installation and Maintenance Guides

pdf
1/8” Atomizing Spray Nozzles

284.16 KB

pdf
1/8” No Drip Atomizing Spray Nozzles

334.60 KB

Atomizing Nozzles PDF Brochure

CAD Drawings

1/4” External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles

1/4″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are great where a high volume of liquid is needed over a concentrated area. Since they are external mix, airflow and liquid flow can be controlled independently. External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are the best choice where thicker liquids for a heavy coating are needed over a narrow band, such as a paint line.

EXAIR’s patented† 1/4” No Drip External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles work in the same way as the EXAIR standard atomizing nozzles do but have the added benefit of positively stopping liquid flow when compressed air is shut off.

All models use stainless steel construction for durability and corrosion resistance.

†Patent #9156045

pattern_img

A Model EF1020SS is used to supply humidification for a corrosion test chamber

Airflow Pattern

Spray Dimensions

Standard Models No Drip Models 1/4″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles
Pressure Width Maximum
Air Liquid A B C Depth
PSI BAR PSI BAR in cm in cm in cm ft m
EF1010SS EF2010SS 5 0.3 3 0.2 4.0 10.2 5.8 14.7 9.5 24.1 6 1.8
25 1.7 5 0.3 5.5 14.0 8.0 20.3 10.0 25.4 12 3.7
25 1.7 20 1.4 6.5 16.5 9.5 24.1 13.0 33.0 13 4.0
50 3.4 20 1.4 6.3 16.0 9.3 23.6 12.0 30.5 16 4.9
75 5.2 40 2.8 6.3 16.5 9.5 24.1 13.0 33.0 18 5.5
EF1020SS EF2020SS 10 0.7 3 0.2 4.5 11.4 7.0 17.8 11.0 27.9 9 2.7
30 2.1 5 0.3 6.0 15.2 10.0 25.4 14.0 35.6 14 4.3
35 2.4 20 1.4 6.5 16.5 11.0 27.9 16.0 40.6 17 5.2
60 4.1 20 1.4 7.5 19.1 11.5 29.2 18.0 45.7 20 6.1
75 5.2 40 2.8 7.5 19.1 12.0 30.5 17.0 43.2 22 6.7
EF1030SS EF2030SS 10 0.7 3 0.2 6.0 15.2 9.0 22.9 12.0 30.5 12 3.7
35 2.4 5 0.3 6.8 17.3 9.0 22.9 12.0 30.5 20 6.1
40 2.8 10 0.7 7.0 17.8 10.0 25.4 13.0 33.0 23 7.0
60 4.1 20 1.4 7.0 17.8 11.0 27.9 14.0 35.6 28 8.5
75 5.2 40 2.8 7.0 17.8 11.0 27.9 14.0 35.6 30 9.1
EF1040SS EF2040SS 15 1.0 3 0.2 6.0 15.2 10.0 25.4 14.0 35.6 13 4.0
30 2.1 3 0.2 6.8 17.3 11.0 27.9 14.0 35.6 17 5.2
50 3.4 10 0.7 7.5 19.1 12.0 30.5 15.0 38.1 22 6.7
60 4.1 20 1.4 8.0 20.3 12.0 30.5 16.0 40.6 25 7.6
80 5.5 40 2.8 7.0 17.8 11.0 27.9 15.0 38.1 27 8.2

Droplet Size and Spray Angle

Droplet size can be adjusted by varying either the air or liquid pressure. An increase in air pressure or decrease in liquid pressure will generally produce a smaller droplet size. The Spray Angle is the trigonometric angle created by the width of the spray pattern and the distance at which it is measured.

Learn More

Liquid Flow Rate

Standard Models No Drip Models 1/4″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles
3 PSI/0.2 BAR Liquid 5 PSI/0.3 BAR Liquid 10 PSI/0.7 BAR Liquid 20 PSI/1.4 BAR Liquid 40 PSI/2.8 BAR Liquid
Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM
PSI BAR PSI BAR PSI BAR PSI BAR PSI BAR
EF1010SS EF2010SS 5 0.3 1.0 3.8 0.8 22.7 10 0.7 1.4 5.3 1.0 28.3 15 1.0 1.9 7.2 1.3 36.8 25 1.7 2.7 10.2 1.8 51.0 45 3.1 3.8 14.4 2.7 76.5
10 0.7 1.0 28.3 20 1.4 1.5 42.5 25 1.7 1.8 51.0 40 2.8 2.5 70.8 60 4.1 3.4 96.3
20 1.4 1.5 42.5 30 2.1 2.0 56.6 40 2.8 2.5 70.8 60 4.1 3.4 96.3 75 5.2 4.1 116
40 2.8 2.5 70.8 50 3.4 2.9 82.1 60 4.1 3.4 96.3 90 6.2 4.7 133 95 6.5 5.1 144
EF1020SS EF2020SS 10 0.7 2.5 9.5 1.0 28.3 15 1.0 3.2 12.1 1.3 36.8 20 1.4 4.3 16.3 1.5 42.5 35 2.4 5.9 22.3 2.2 62.3 50 3.4 7.5 28.4 2.9 82.1
20 1.4 1.5 42.5 25 1.7 1.8 51.0 30 2.1 2.0 56.6 50 3.4 2.9 82.1 60 4.1 3.4 96.3
30 2.1 2.0 56.6 40 2.8 2.5 70.8 50 3.4 2.9 82.1 70 4.8 3.8 108 80 5.5 4.3 122
50 3.4 2.9 82.1 60 4.1 3.4 96.3 70 4.8 3.8 108 90 6.2 4.7 133 100 6.9 5.2 147
EF1030SS EF2030SS 10 0.7 4.4 16.7 3.5 99.1 20 1.4 5.5 20.8 5.3 150 25 1.7 7.6 28.8 6.1 173 40 2.8 11.0 41.6 8.4 238 50 3.4 14.0 53.0 10.0 283
20 1.4 5.3 150 30 2.1 6.9 195 35 2.4 7.6 215 50 3.4 10.0 283 60 4.1 11.5 326
30 2.1 6.9 195 40 2.8 8.4 238 50 3.4 10.0 283 70 4.8 12.7 360 80 5.5 13.7 388
50 3.4 10.0 283 60 4.1 11.5 326 70 4.8 12.7 360 90 6.2 14.8 419 95 6.5 15.1 428
EF1040SS EF2040SS 15 1.0 10.0 37.9 4.4 125 25 1.7 13.5 51.1 6.1 173 35 2.4 18.8 71.2 7.6 215 45 3.1 27.6 104 9.2 261 55 3.8 31.0 117 10.7 303
25 1.7 6.1 173 35 2.4 7.6 215 45 3.1 9.2 261 55 3.8 10.7 303 65 4.5 12.2 345
40 2.8 8.4 238 50 3.4 10.0 283 60 4.1 11.5 326 70 4.8 12.7 360 80 5.5 13.7 388
50 3.4 10.0 283 60 4.1 11.5 326 80 5.5 13.7 388 90 6.2 14.8 419 100 6.9 16.2 459

Dimensions

Standard Models
No Drip Models

Models

1/4″ External Mix Flat Fan Pattern Atomizing Nozzles
Maximum Liquid Flow Rate Standard
No Drip
Model
GPH LPH
3.8 14.4 BPEF1010SS BPEF2010SS
7.5 28.4 BPEF1020SS BPEF2020SS
14.0 53.0 BPEF1030SS BPEF2030SS
31.0 117.0 BPEF1040SS BPEF2040SS

 

Mounting Brackets For Atomizing Spray Nozzles
Model Description
901786 Mounting Bracket for 1/8″ Atomizing Spray Nozzles
901318 Mounting Bracket for 1/4″ Atomizing Spray Nozzles
901556 Mounting Bracket for 1/2″ Atomizing Spray Nozzles

Accessories

EFC Electronic Flow Control
Turn off the compressed air when it isn’t needed

EXAIR's EFC™ is a user-friendly electronic flow control for compressed air that is designed to minimise compressed air use on blowoff, drying, cooling, conveying and static elimination operations. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present. The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.

Learn More
Filters, Regulators, Valves & More

With proper filtration of dirt, moisture and oil from the compressed air supply, EXAIR compressed air products will operate for years with no maintenance required. Use a 5 micron or smaller filter separator on the compressed air supply. To prevent problems associated with oil, use a 0.03 micron or smaller oil removal filter on the compressed air supply. Pressure regulators permit easy selection of the operating pressure, providing infinite control of flow, force and air consumption.

Learn More

Installation and Maintenance Sheets

pdf
1/4” & 1/2” Atomizing Spray Nozzles

255.94 KB

pdf
1/4” & 1/2” No Drip Atomizing Spray Nozzles

283.83 KB

Atomizing Nozzles PDF Brochure

CAD Drawings

1/2” External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles

1/2″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are great where a high volume of liquid is needed over a concentrated area. Since they are external mix, airflow and liquid flow can be controlled independently. External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles are the best choice where thicker liquids for a heavy coating are needed over a narrow band, such as a paint line.

EXAIR’s patented† 1/2” No Drip External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles work in the same way as the EXAIR standard atomizing nozzles do but have the added benefit of positively stopping liquid flow when compressed air is shut off.

All models use stainless steel construction for durability and corrosion resistance.

†Patent #9156045

pattern_img

Airflow Pattern

Spray Dimensions

Standard Model No Drip Model 1/2″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles
Pressure Width Max
Air Liquid A B C Depth
PSI BAR PSI BAR in cm in cm in cm ft m
EF5010SS EF6010SS 35 2.4 3 0.2 15 38 18.5 47 22 56 25 7.6
50 3.4 5 0.3 15 38 19 48 23 58 31 9.4
70 4.8 10 0.7 15 38 20 51 25 64 33 10.1
90 6.2 15 1.0 15 38 20 51 25 64 35 10.7

Droplet Size and Spray Angle

Droplet size can be adjusted by varying either the air or liquid pressure. An increase in air pressure or decrease in liquid pressure will generally produce a smaller droplet size. The Spray Angle is the trigonometric angle created by the width of the spray pattern and the distance at which it is measured.

Learn More

Liquid Flow Rate

Standard Model No Drip Model 1/2″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles
3 PSI/0.2 BAR Liquid 5 PSI/0.3 BAR Liquid 7 PSI/0.5 BAR Liquid 10 PSI/0.7 BAR Liquid 15 PSI/1.0 BAR Liquid
Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM Air Pressure GPH LPH SCFM SLPM
PSI BAR PSI BAR PSI BAR PSI BAR PSI BAR
EF5010SS EF6010SS 30 2.1 141 534 30.2 854 40 2.8 186 704 36.6 1037 45 3.1 218 825 39.9 1130 55 3.8 264 999 46.4 1314 80 5.5 303 1147 56.0 1586
35 2.4 34.0 961 45 3.1 40.4 1144 55 3.8 47.0 1331 60 4.1 49.75 1409 85 5.9 60.0 1699
40 2.8 37.3 1055 55 3.8 47.4 1342 60 4.1 49.5 1402 70 4.8 52.84 1496 90 6.2 61.4 1739
45 3.1 40.8 1155 60 4.1 50.0 1416 70 4.8 56.8 1609 80 5.5 59.7 1691 100 6.9 67.6 1914

Dimensions

Standard Model
No Drip Model

Models

1/2″ External Mix Narrow Angle Flat Fan Pattern Atomizing Nozzles
Maximum Liquid Flow Rate Standard
Model
No Drip
Model
GPH LPH
303.0 1,147.0 BPEF5010SS BPEF6010SS

 

Mounting Brackets For Atomizing Spray Nozzles
Model Description
901786 Mounting Bracket for 1/8″ Atomizing Spray Nozzles
901318 Mounting Bracket for 1/4″ Atomizing Spray Nozzles
901556 Mounting Bracket for 1/2″ Atomizing Spray Nozzles

Accessories

EFC Electronic Flow Control
Turn off the compressed air when it isn’t needed

EXAIR's EFC™ is a user-friendly electronic flow control for compressed air that is designed to minimise compressed air use on blowoff, drying, cooling, conveying and static elimination operations. The EFC combines a photoelectric sensor with a timing control that limits compressed air use by turning it off when no part is present. The timing control permits easy tuning to the application requirements while providing flexibility in sensing distance.

Learn More
Filters, Regulators, Valves & More

With proper filtration of dirt, moisture and oil from the compressed air supply, EXAIR compressed air products will operate for years with no maintenance required. Use a 5 micron or smaller filter separator on the compressed air supply. To prevent problems associated with oil, use a 0.03 micron or smaller oil removal filter on the compressed air supply. Pressure regulators permit easy selection of the operating pressure, providing infinite control of flow, force and air consumption.

Learn More

Installation and Maintenance Sheets

pdf
1/4” & 1/2” Atomizing Spray Nozzles

255.94 KB

pdf
1/4” & 1/2” No Drip Atomizing Spray Nozzles

283.83 KB

Atomizing Nozzles PDF Brochure

CAD Drawings

Catalogue Downloads

Please register or login to access our catalogue downloads.

Forgot your Login or Password?

Copyright 2019 © Compressed Air Australia | Website Design Web365 Darwin