Adjustable Spot Cooler

Adjustable Spot Cooler™ Intelligent Compressed Air Product OSHA Seal

With the turn of a knob, precise temperature settings to minus 30°F (-34°C) from your compressed air supply for spot cooling.


What is the Adjustable Spot Cooler?

A low cost, reliable, maintenance free solution to a variety of industrial spot cooling problems. With the turn of a knob, you can select the temperature best suited to your application. The Adjustable Spot Cooler provides a precise temperature setting from -30°F (-34°C) to room temperature.

The Adjustable Spot Cooler incorporates a vortex tube that converts an ordinary supply of compressed air into cold air. 

  • Temperatures from -30° to +70°F (-34°C to 21°C)
  • Parts included for flow rates from 15 to 30 SCFM (425 to 850 SLPM) - 25 SCFM (708 SLPM) generator factory installed
  • Refrigeration up to 2000 Btu/hr. (504 Kcal/hr.)

A swivel magnetic base provides easy mounting and portability.  Flexible tubing that holds its position directs the cold air.  No moving parts or CFC's assures maintenance free operation.

Spot Coolers Replace Liquid Coolants
The Adjustable Spot Cooler replaces flood coolant and eliminates hours of cleanup on a cast iron machining operation.
 

Why The Adjustable Spot Cooler?

The Adjustable Spot Cooler is quiet (less than 75 dBA), easily set with a thermometer and holds the temperature setting. It's ideal for applications where mist or liquid cooling can not be used due to part contamination or cost. Tolerances, product finish and production rates can improve dramatically.

The Adjustable Spot Cooler is available with either a single point or dual point hose kit. The single point system (Model 3825) is recommended for cooling a small surface like solder joints, hot melts or drilled plastics. The dual point system (Model 3925) is recommended when heat is generated over a larger surface area.

Cooling Extruded PVC Hose
PVC hose is cooled at the exit of an extruder so it can be coiled immediately.
 

Applications

Advantages

  • Adjusting thermostats
  • Cooling solder
  • Cooling machined plastics
  • Setting hot melts
  • Cooling welding horns
  • Cooling molded plastics
  • Electronic component cooling
  • Cooling gas samples
  • Cooling environmental chambers
  • No moving parts
  • Low cost
  • Interchangeable generators
  • No electricity or chemicals
  • Instant cold air
  • Quiet - less than 75 dBA
  • Swivel magnetic base
  • Small, lightweight
  • Maintenance free

How the Adjustable Spot Cooler Works

Adjustable Spot Cooler Diagram
The Adjustable Spot Cooler incorporates a vortex tube to convert an ordinary supply of compressed air into two low pressure streams, one hot and one cold. With the turn of a knob, the temperature control valve allows some hot air to flow through a muffling sleeve and out the hot air exhaust. The opposite end provides a cold airstream that is muffled and discharged through the flexible hose, which directs it to the point of use. The swivel magnetic base provides easy mounting and portability.

Dimensions

Adjustable Spot Coolers produce cold air from compressed air
The Model 3825 Adjustable Spot Cooler can produce temperatures from -30° to +70°F (-34° to +21°C).
 

Adjusting the Spot Cooler

The Adjustable Spot Cooler System can produce a full range of airflows and temperatures as determined by the knob setting and a small internal part called a generator. The generators control the SCFM (SLPM) of air consumption and are easily interchangeable.

The Adjustable Spot Cooler has a 25 SCFM (708 SLPM) generator installed that produces up to 1,700 Btu/hr. (429 Kcal/hr.). If less cooling is desired, the 15 SCFM (425 SLPM) generator which delivers 1,000 Btu/hr. (252 Kcal/hr.) can be installed. If more cooling is needed, the 30 SCFM (850 SLPM) generator can be installed for up to 2,000 Btu/hr. (504 Kcal/hr.).

Keep Electrical Components Cool
Electronic components stay cool during a soldering operation.
 

Controlling the Cold Air

The Adjustable Spot Cooler gives instant cold air when filtered compressed air is supplied to it. Cycling on and off is a good way to save air. For on and off control, use a Model 9012 Manual Shutoff Valve. To turn the Adjustable Spot Cooler on with the machine, Model 9020 Solenoid Valve may be used and wired through the machine control switch. The EFC electronic flow control can also be used.

Specifications

Pressure SupplyAir ConsumptionSound Level
PSIG BAR SCFM SLPM dBA
100 6.9 15 425 72
100 6.9 *25 708 73
100 6.9 30 850 74
* 25 SCFM (708 SLPM) generator is factory installed

Adjustable Spot Cooler Models

BSP Threads Available - Contact Compressed Air Australia
Model #
Description
5901
Single Point Hose Kit (included with 3825)
5901
Dual Point Hose Kit (included with 3925)
9001
Auto Drain Filter Separator, 3/8 NPT, 65 SCFM (1841 SLPM)
9005
Oil Removal Filter, 3/8 NPT, 15- 37 SCFM (425-1048 SLPM)
9012
Manual Shutoff Valve, 1/4 NPT

Models

   
Model 3725 Adjustable Spot Cooler
Model 3725 Adjustable Spot Cooler Only.
Spot Cooler with drain filter separator
Model 3825 Adjustable Spot Cooler System includes the Adjustable Spot Cooler, Automatic Drain Filter Separator (not shown), single point hose kit with cone and fan nozzle, swivel magnetic base and (2) additional generators.
Spot Cooler with dual point hose kit
Model 3925 Adjustable Spot Cooler System includes the Adjustable Spot Cooler, Automatic Drain Filter Separator (not shown), dual point hose kit with cone and fan nozzles, swivel magnetic base and (2) additional generators.

Installation and Maintenance Sheets

Back to Top

Adjustable Spot Cooler

getacro
These files are in the Adobe Acrobat PDF format. The viewer is free and is available at www.adobe.com
Back to Vortex Tubes & Spot Cooling Home

home


Compressed Air Australia

GPO Box 2792, Darwin,
Northern Territory 0801, Australia
Tel: +61 8 8983 3999
Fax: +61 8 8983 3900